VAV Terminal Monitoring & Control.

Per-box monitoring and control for all-air office floors — one AHU feeding many variable-air-volume boxes. Adds deep per-terminal visibility (airflow delivery, damper saturation, minimum ventilation, loop stability) and control that scales by tier: visibility and ad-hoc command at Essential, managed alarm ops at Managed, proactive device-level control at Optimized. Installs and operates the terminal controller — it does not replace defective field devices.

Type Domain-specific
Domain hvac
Segments offices
Pricing Recurring charge + hardware charge
01 Executive Summary

Impact, and what it solves.

Impact: Turns an all-air floor from a set of boxes seen only in aggregate into individually monitored and operated terminals — a starved zone, a saturated damper starving the floor, an under-ventilated occupied room, or a hunting loop wearing its actuator is caught and, at Optimized, corrected at the box before a tenant feels it. Packages a VAV floor as a repeatable 'pro' bundle instead of a proposal re-derived each time.

What it solves: An all-air office floor runs one air handler feeding many VAV boxes, and comfort and energy on that floor are decided box by box — the damper airflow each terminal delivers to its zone. The base HVAC product's zone and fan-coil model can see the floor but not operate the individual boxes. This add-on layers per-terminal depth on the boxes: it monitors each box's airflow delivery, damper saturation (the worst-case box that drives the air handler's static-pressure reset), minimum ventilation, and control-loop stability, and it controls the terminal at a depth that scales with the tier. At Essential the customer's team gets deep per-box visibility and can issue ad-hoc setpoint and schedule commands themselves; at Managed, Keedian Ops runs the new terminal alarms 24/7 — triage, remote resolution, dispatch, and RCA; at Optimized, Keedian drives device-level control proactively — commanding dampers within their authority and running occupancy and static-reset optimization, with an audit trail on every command. The add-on installs and operates the box controller (a Siemens Desigo DXR2 room-automation controller per box, replacing dead LonTalk legacy controllers) and its sensing and actuation; it does not include replacing field devices (a failed damper actuator, a drifted flow sensor) found defective — those are scoped case by case.

Main value drivers
Customer experience Energy savings Asset lifespan
02 Optimization Metrics

The metrics you'll want to optimize.

These are the operational metrics this add-on monitors and alarms on. Keedian surfaces them and, where the contract includes managed service, triages them; acting on the physical asset stays with you and your vendors.

The core metrics are summarized below. Full methodology, thresholds, diagnosis steps, and escalation criteria are in the Metrics Catalog.

HVAC · Operational discipline
Setpoint Compliance

Percentage of time the thermostat setpoint matched the agreed corporate policy. Measures whether the system is being operated as configured — independent of whether the physical outcome was reached. Most reliable signal of override patterns at the site level.

Full detail → Metrics Catalog
HVAC · Comfort outcome
Temperature Compliance

Percentage of time actual space temperature was within the expected range during evaluated hours. Measures the physical outcome — whether the equipment is delivering the required comfort. Correct setpoints with poor temperature compliance is the clearest signal of an equipment or capacity issue.

Full detail → Metrics Catalog
HVAC · Operational signal
Runtime

Average compressor hours per day while actively running. The baseline signal for operational health — flags equipment running too long (degraded efficiency or capacity issues) and too short (scheduling or data problems) before the pattern becomes a larger issue.

Full detail → Metrics Catalog
HVAC · VAV terminal · Equipment performance
VAV Airflow & Damper Performance

Whether each VAV box actually delivers the supply airflow its control loop is calling for — measured airflow against the box's commanded setpoint. A box that sits below its airflow setpoint while the damper is already open is starved: a stuck damper, a collapsed flex duct, low upstream static, or an undersized box. The earliest per-terminal signal that a zone is about to lose comfort, weeks before the complaint.

Full detail → Metrics Catalog

Each metric includes definition, detection logic, diagnosis steps, recommended actions, escalation criteria, and prevention controls. Thresholds are reference values to be calibrated per client.

View Metrics Catalog →
03 Scope

What's included.

Every box delivers the airflow it calls for, occupied zones hold their ventilation floor, the air handler's static reset follows the worst-case box, and hunting loops are settled before the actuator wears — with control depth scaling from visibility (Essential) to proactive device command (Optimized). Expected (pending validation) — offices have no named Keedian reference deployment yet.

Model A, scoped per box: a Siemens Desigo DXR2 room-automation controller (replaces the legacy LonTalk controller), a QMX3 room unit for space temperature, a box airflow/velocity sensor, and a modulating damper actuator. Under Model B the same points are read from the BMS where exposed. No sensor-by-sensor cost modeling — instrumentation is scoped per box.

  • Ad-hoc per-terminal dashboard — airflow delivery, damper position, minimum ventilation, and loop stability per box on one floor view, with the worst-case box highlighted
  • Reactive alarms on the terminal metrics (starved box, saturated damper, under-ventilation, hunting loop)
  • Ad-hoc setpoint and schedule command per box, floor, or zone (customer-operated at Essential)
  • Predictive alarms on terminal trends — actuator wear, slow delivery degradation (optional)
  • At Optimized, proactive device-level control — damper command within authority and occupancy / static-reset optimization, with an audit trail on every command

At Managed, the terminal-metric alarms are run on the same 24/7 basis as the rest of the contract — triaged, resolved remotely where possible, dispatched where not, and closed with RCA. At Optimized, Keedian additionally drives the boxes proactively (damper command and occupancy / static-reset optimization). Replacing a defective field device — a failed actuator or flow sensor — is scoped as a field-services item, not part of the managed fee.

04 Hardware & pricing

What it needs, and how it is charged.

Hardware Terminal instrumentation scoped per box (Desigo DXR2 controller replacing legacy, QMX3 room unit, airflow/velocity sensor, modulating damper actuator); field-device replacement scoped separately
Pricing Recurring charge + hardware charge