Every add-on Keedian offers, one per row. Each is either Domain-specific — it belongs to a product domain (HVAC, Refrigeration, Lighting, Energy) — or Transversal, applying across any contracted product. Customer profiles, products, and tiers activate add-ons on top of their base offering. Click a name to open its detail page (description, hardware, value levers, pricing, and related capabilities).
| Add-on | Type | Domain |
|---|---|---|
| Defrost Cycle Monitoring & Optimization Monitors each refrigerated case's defrost cycles from the controller — whether a cycle starts on schedule, terminates on its configured condition within its expected duration, and lets the case recover. Catches a missed, run-long, or unterminated defrost before it ices the coil and pushes the case out of band. |
Domain-specific |
refrigeration
|
| Refrigeration Rack Monitoring & Protection Monitors the centralized refrigeration rack from its controller — discharge and suction pressure against commissioned limits, protection trips and resets, and the pump-down sequence. A rack fault affects every case the rack feeds at once, so catching it early protects the whole rack's product. |
Domain-specific |
refrigeration
|
| Food Safety Compliance (HACCP/FDA) Auditable temperature reporting per asset, critical event traceability, and cold-chain regulatory documentation. Food safety compliance ready for inspection. |
Domain-specific |
refrigeration
|
| Foodservice Equipment Monitoring Extends monitoring to critical non-refrigeration assets: ovens, fryers, salamander broilers, deli stations. Reduces downtime in hot food and deli operations. |
Domain-specific |
refrigeration
|
| Indoor Air Quality (IAQ) Monitoring Tracks CO2, VOCs, and PM2.5 to validate ventilation effectiveness and support employee/customer wellness reporting. Useful for compliance with stricter indoor air standards. |
Domain-specific |
hvac
|
| Air Curtain Monitoring & Control Monitors and controls entrance air curtains — on/off state, runtime, and activation compliance — so the thermal barrier is actually running when doors are open. |
Domain-specific |
hvac
|
| Restroom Odor Monitoring Tracks restroom air quality (VOC / odor index) and flags spikes so cleaning is dispatched before customers notice. |
Domain-specific |
hvac
|
| HVAC Refrigerant Monitoring & Compliance Predictive charge-loss and refrigerant-leak indicators on refrigerant-bearing HVAC equipment, plus auditable tracking of charge, leak events, and recovery. Covers rooftop/package units, split systems, heat pumps, and chillers where compatible telemetry exists. Supports EPA Section 608 / state-level refrigerant regulations. |
Domain-specific |
hvac
|
| Refrigeration Refrigerant Monitoring & Compliance Predictive charge-loss and refrigerant-leak indicators on commercial-refrigeration systems, plus auditable tracking of charge, leak events, and recovery. Covers racks, condensing units, walk-ins, coolers, and display cases where compatible telemetry exists. Supports EPA Section 608 / state-level refrigerant regulations. |
Domain-specific |
refrigeration
|
| Chiller Plant Monitoring Monitoring for the central cooling plant (Chiller Plant) — chilled-water and cooling-tower ΔT, operational-sequence compliance, and plant efficiency (kW per ton) where the plant is metered. Instruments the building's single largest cooling load and surfaces its operational metrics and alarms; it does not control the plant. |
Domain-specific |
hvac
|
| VAV Terminal Monitoring & Control Per-box monitoring and control for all-air office floors — one AHU feeding many variable-air-volume boxes. Adds deep per-terminal visibility (airflow delivery, damper saturation, minimum ventilation, loop stability) and control that scales by tier: visibility and ad-hoc command at Essential, managed alarm ops at Managed, proactive device-level control at Optimized. Installs and operates the terminal controller — it does not replace defective field devices. |
Domain-specific |
hvac
|
| Air Handler (AHU) Monitoring & Control Deep monitoring and control for the office air handler that feeds an all-air floor — supply-air temperature compliance, duct static pressure (reset to follow the VAV boxes), fan/VFD performance, filter differential pressure, and chilled-water valve/coil performance, plus economizer effectiveness where an outdoor-air damper exists. Control scales by tier. Installs and operates the plant controller — it does not replace defective field devices. |
Domain-specific |
hvac
|
| Emergency Lighting Compliance Auditable monthly self-test reporting, battery health monitoring, and code compliance evidence (NFPA 101, OSHA) for emergency egress lighting. Replaces manual monthly walkthroughs. |
Domain-specific |
lighting
|
| Exterior Lighting Photocell Control Astronomical clock + photocell-driven control of parking-lot, canopy, signage, and facade lighting. Eliminates manual schedule updates for daylight savings, seasonal shifts, and regional variation across the fleet. |
Domain-specific |
lighting
|
| Utility Data Integration Standard connectors — Green Button, EnergyStar Portfolio Manager, and major utility APIs — pull interval consumption and cost straight from the utility, with no on-site hardware. Normalizes each utility's billing format and reconciles the pulled data against meter telemetry. |
Domain-specific |
energy
|
| Tariff Optimization Program Continuous tariff analysis with rate-schedule recommendations and utility-incentive enrollment management. |
Domain-specific |
energy
|
| Utility Bill Audit & Recovery Automated audit of utility bills against tariff schedules and meter data. Identifies billing errors, incorrect rate classes, and overcharges. Manages refund recovery. |
Domain-specific |
energy
|
| Demand Response Aggregation Enrolls eligible sites and controllable loads in utility demand response programs at the portfolio level. Manages event response, post-event verification, and incentive collection. HVAC and other climate equipment are the primary curtailment lever. |
Domain-specific |
energy
|
| Renewable Energy Integration Integration with on-site solar, battery storage, or PPA contracts. Tracks generation vs consumption, validates PPA invoicing, supports renewable energy certificates (RECs) accounting. |
Domain-specific |
energy
|
| Vendor Performance Management Tracks vendor response time, first-visit resolution rate, and cost per ticket across any contracted product. |
Transversal | All products |
| Cross-Asset Portfolio Benchmarking Compare stores across all contracted products. Identifies outliers in consumption, failures, and operating cost. |
Transversal | All products |
| BMS / EMS Integration Extension Extend the integration to additional systems not included in the product's base Model B. |
Transversal | All products |
| Custom CMMS Integration Deep integration with your CMMS beyond the standard. |
Transversal | All products |
| Data as a Service Programmatic access to Keedian's normalized operational data for your analytics, BI, or data lake. |
Transversal | All products |
| Ad-Hoc Dashboards & Reporting Custom dashboards and one-off reports built to your spec, on top of the data Keedian already collects. |
Transversal | All products |
| Refrigeration Monitoring Temperature and operating-status monitoring for office cafeteria, pantry, and vending refrigeration — alarms on warm cases and outages so food-safety risk is caught before stock is lost. |
Transversal | All products |
| UPS & Continuity Monitoring Monitoring of the electrical-continuity chain — UPS and standby generators, with the ATS and main switchboard as supporting signals — so a backup that is not ready surfaces before the outage it was meant to cover, not during it, and the site stays online: an office building's tenants and critical rooms, or a bank branch's ATMs, teller and core-banking systems, security, and comms. Monitors readiness ("will the backup take the load, and for how long?"), not just "broken now." Continuity links to the other monitoring add-ons for the layers they already cover — Chiller Plant Monitoring (critical-environment cooling), Fire Detection & Suppression Monitoring, and Vertical Transport Monitoring — which read alongside continuity but stay separate add-ons. |
Transversal | All products |
| Vertical Transport Monitoring Monitoring of elevators and escalators — operating status, fault codes, and out-of-service events — so a stoppage is detected and routed to the maintenance provider the moment it happens. |
Transversal | All products |
| Fire Detection & Suppression Monitoring Monitoring of fire detection and suppression systems — panel status, supervisory and trouble signals, and test/inspection records — so a supervisory fault or a missed inspection is caught and routed to the life-safety provider. |
Transversal | All products |